Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Pусский |
| No.12984400
| No.12984400
- Product Categories
- Friendly Links
| Information Name: | Dewpoint Transmitter |
| Published: | 2014-06-13 |
| Validity: | 900 |
| Specifications: | DMT143 |
| Quantity: | 100.00 |
| Price Description: | |
| Detailed Product Description: | About Vaisala Dewpoint Transmitter (Vaisala) DRYCAP? DMT143 Dewpoint Transmitter is a compact sensor dew point measurement instruments, which can be installed directly at the maximum 50 bar (725 psia) pressure system. Vaisala (Vaisala) DRYCAP? Sensor technology has long-term high-performance operational performance. The sensor is fully withstand humid environments, so DMT143 transmitter in the water splashing industrial applications can have very good performance, these applications include car during the process stages of system failure or pipe condensation. Sensors also extremely tolerant particulate impurities, oil and most chemicals, not sensitive to changes in flow velocity. Calibration cycle longer DMT143 calibration period up to two years time. Besides using the Vaisala (Vaisala) of DM70 hand-held dewpoint meter can to DMT143 online than to confirm its performance, without having to disassemble it from the system. If you need to adjust, take it to Vaisala Service Center. Process during normal operation, automatic calibration software also work online. When measuring accuracy can not be guaranteed, corrective work automatically. Easy to install DMT143 Dewpoint Transmitter has many features to choose from, including different output, mounting options and alarm LED lights. Due to small size, light weight, DMT143 in narrow space or a small size pipe is very easy and fast to install. LED lights for ultra-high dew point alarm, factories can be pre-set trigger point, with Vaisala DM70 hand-held meter table or a PC can also be re-set. Dewpoint Transmitter Features / Benefits 1, compact dew point transmitters, suitable for small industrial dryer applications 2, Vaisala (Vaisala) with automatic calibration function DRYCAP? Sensor technology 3, two-year calibration cycle time 4, dewpoint measurement range -60 ... +60 oC (-76 ... +140 ° F) 5, Accuracy ± 2 oC (± 3.6 oF) 6, anti-condensation dew 7, 8 fast response time, and Vaisala (Vaisala) Dewpoint Meter DM70 compatible handheld 9, traceable to NIST calibration (including calibration *) 10 user via RS485 port, convenient maintenance and data transmission 11, LED light dew dew point transmitter overrun alarm Technical indicators to measure parameters of the dew point temperature measurement range (typical) -60 ... +60 ° C (-76 ... +140 ° F) Td analog output range Option 1 -80 ... +20 ° C (-112 ... +68 ° F) Td Option 2 -80 ... +20 ° C (-112 ... +68 ° F) Td at atmospheric pressure dew point Option 3 Custom Range Accuracy, air or nitrogen ± 2 ° C (± 3.6 ° F) Td (see below) when the dew point is below 0 ° C (32 ° F), the transmitter output frost point response time 63% [90%], the gas temperature at +20 ° C and pressure of 1 bar when -60 -> -20 ° C Td (-76 -> -4 ° F Td) 5 s [15 s] -20 -> -60 ° C Td (-4 -> -76 ° F Td) 45 s [10 min] PPM volume concentration measurement range (typical) 10 ... 40000 ppm accuracy, +20 ° C (+68 ° F), 1 bar1 ppm + 20% 63% response time for reading [90 %], the operating environment of non-corrosive gases measured gas temperature *) -40 ... +60 ° C (-40 ... +140 ° F) Relative humidity 0 ... 100% RH Pressure *) 0 .. time. 50 bara (725 psia) sample flow rate has no effect on the measurement accuracy *) when the gas temperature as low as -40 ° C (-40 ° F) or high pressure to 50 bar (725 psia), the supply voltage must be 24. .. 28 VDC. Output Analog output (corresponding range can be changed) 4 ... 20 mA (3 lines), 0 ... 1 V / 5 V, 1 ... 5 V resolution of 0.002 mA current output voltage output resolution of 0.3 mV typical Temperature coefficient of output range of 0.005% / ° C Digital output RS-485, Non-Isolated Vaisala industrial protocols cable connector 4 - pin M8 (IEC 60947-5-2) conventional sensors Vaisala DRYCAP 180D recommended calibration cycle given accuracy in the range? Supply voltage Supply voltage 12 ... 28 VDC output current when the output voltage is 2 years when 18 ... 28 VDC supply current when the normal measurement of the maximum load current 10mA + self-diagnostic phase pulse maximum 220 mA maximum current output load 500 Ohm output load voltage minimum 10 kOhm Case Material Stainless steel (AISI316L) sensor protection stainless steel sintered filter mechanical interface ISO G1 / 2 "or NPT 1/2 Protection class IP66 (NEMA 4) Storage temperature range -40 ... +60 ° C (-40 ... +140 ° F) Weight pipe thread 90g (3.2oz) NPT threaded 100g (3.5oz) meet EMC standards EN61326-1, electronic equipment for measurement, control and laboratory use in industrial environments. |
Admin>>>
You are the 11474 visitor
Copyright © GuangDong ICP No. 10089450, Shenzhen Technology Co., temperature and humidity sensors All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 11474 visitor
Copyright © GuangDong ICP No. 10089450, Shenzhen Technology Co., temperature and humidity sensors All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility

